INTELLIGENT INTERFACES MICROPRINT 45CXA/ MICROPRINT 45CH(Version 1.4) INSTRUCTION MANUAL GENERAL DESCRIPTION The MicroPrint 45CXA/CH interface converter allows parallel printers with Centronics parallel interfaces to be used with the IEEE-488 (HP-IB/GPIB) bus. The device supports the IEEE-488 subsets: SHO, AHI, TO, TEO, L1, LEO, SRO, RLO, PPO, DCO, DTO, and CO. The MicroPrint 45CXA/CH is an interface converter, not a printer emulator. Your software must send the correct data format to the MicroPrint and printer. Consult your computer or software manual to ensure the printer you wish to use is supported before connecting the MicroPrint. The input connector is a 24 pin IEEE-488 female "D" connector with metric screw lock hardware. The output connector is a female 25 pin "DB25" type connector with screw lock hardware. The pinout of the parallel port is compatible with the IBM PC-type parallel printer interface cable. The MicroPrint 45CXA is powered by a ETL/CSA rated 9 VAC wall-mounted power adapter. The MicroPrint 45CXA/CH is a one-way converter: from HP-IB to Parallel. DO NOT ATTEMPT TO USE IT IN THE OPPOSITE DIRECTION (i.e., with the MicroPrint 45CXA Centronics output connected to a computer parallel output port).
INSTALLATION PROCEDURE 1) Set the MicroPrint 45CXA/CH to the correct HP-IB address. The MicroPrint is set at the factory for a listen address of 1 . To change the address, set the switch on the side of the MicroPrint for the desired HP-IB address or for "listen always". (Refer to the ADDRESS SWITCH SETTINGS section of this manual.) 2) Attach the HP-IB cable from the computer/controller to the "HP-IB" connector on the MicroPrint. Attach the cable from the printer or other peripheral to the "Centronics" connector on the MicroPrint. NOTE: Ensure that both connectors are on securely BEFORE tightening the retaining screws. The latter should screw into the connectors easily and be "finger tight." 3) Plug the wall mount power supply connector into the female connector located on the side of the MicroPrint. Plug the wall mount power supply into an AC outlet which will activate the red LED indicator next to the Centronics connector. The MicroPrint is now ready for use. NOTE: Since the MicroPrint reads the address switch setting only during power-up, it is necessary to interrupt the DC input power to the MicroPrint after any change to the switch settings. Also, it is advisable to "power up" the MicroPrint 45CXA/CH after other devices on the HP-IB bus. IN CASE OF DIFFICULTY/TROUBLE ISOLATION If no output is obtained on the printer, or the output is incorrect, after the MicroPrint 45CXA/CH is installed, check the following before calling your Intelligent Interfaces representative: 1) Check that the MicroPrint 45CXA/CH is connected to the "low speed" HP-IB output port on the computer. 2) Check that the MicroPrint 45CXA/CH and printer are set to the same HP-IB address. 3) Check that the MicroPrint is connected to the printer with a 25 pin male to 36 pin male parallel printer cable(see PRINTER CABLE/SIGNAL WIRING table below). 4) Ensure that all cable connections at the computer, MicroPrint, and printer are seated correctly and tight. 5) For HP-UX applications, use driver #21 (primitive 8 bit driver) with the MicroPrint. For HP RISC computers, use the INSTR0 "driver." 6) Check that your computer has a "driver" (software routine, usually listed in a set-up or configuration menu) that supports the printer you are using. The MicroPrint is an interface converter, not a printer emulator. The computer must be configured for the parallel printer with which it is to be used. A configuration error is usually evidenced by "stray" or strange characters being printed. Consult your software documentation to properly "set-up" your printer with your computer. APPLICATION SUPPORT For application support, contact Intelligent Interfaces Inc. by mail, phone or FAX at:: Intelligent Interfaces, Inc. P.O. Box 99 Mill Spring, NC 28756 1-800-842-0888 (828)863-1210 FAX: (828) 863-1209 Email: service@intelligentinterfaces.com ADDRESS SWITCH SETTINGS
Positions 1 through 5 and position 7 of SW1 are set to "1", or ON, by rocking, the individual switch controls toward the 1 ("ON") position. Positions 6 & 8 of SW1 are not used. To set the MicroPrint to the Listen Always mode, turn Switch Position 7 ON. When Position 7 is on, the settings of the other switch positions are ignored by the MicroPrint. NOTE: When Position 7 of the switch is in the "ALWAYS", or ON, position, the MicroPrint accepts all data on the bus regardless of the address to which the data is sent. SPECIFICATIONS DATA RATE: *30,000 Bytes/sec MECHANICAL Size (cm): 5.75"(14.6)L X 3.6"(9.1)W X 1.12"(2.8)D Weight(kg): Approximately 8 ounces (0.23) ENVIRONMENTAL Operating Temperature: +10 to +40 degrees C Humidity: 5% to 80% RH, Non-Condensing ELECTRICAL Input Connector(HP-IB): 24 Pin Female "D", metric screw locks Output Connector(Parallel): 25 Pin Female Sub-D Power Adapter-Domestic/Canada: Input: 120Vac, 60Hz, 10W; Output: 9Vac, 600 mA Power Adapters - Europe / Intercon
*Maximum data rate possible. Actual data throughput will vary depending on computer/controller hardware, software, and peripheral used. Warranty Intelligent Interfaces Inc. certifies that the product purchased was carefully inspected and tested at the factory prior to shipment, and has been found to meet all published specifications. ONE-YEAR LIMITED WARRANTY: In the U.S. and abroad, all products purchased from Intelligent Interfaces Inc. are warranted against defects in materials and workmanship for one year from the date of purchase. If you transfer ownership, this warranty is automatically transferred to the new owner and remains in effect for the original one year period. WHAT IS NOT COVERED UNDER THE WARRANTY: This warranty does not apply if the product has been damaged by accident or misuse, or as a result of service or modification by other than an authorized Intelligent Interfaces Inc. representative, or by hardware, software, interfacing, or peripherals or cables not provided by Intelligent Interfaces Inc.. Intelligent Interfaces Inc. shall have no obligation to modify or update hardware or software products once manufactured. Modifications or updates to Intelligent Interfaces Inc. hardware or software products will be according to the agreement between the parties EXCEPT AS OTHERWISE SPECIFICALLY PROVIDED HEREIN, THERE ARE NO REPRESENTATIONS OR WARRANTIES OF ANY KIND, EXPRESS OR IMPLIED, WITH RESPECT TO THE CONDITION OR PERFORMANCE OF INTELLIGENT INTERFACES INC.'S PRODUCTS, IT'S MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. INTELLIGENT INTERFACES INC. SHALL HAVE NO LIABILITY TO IT'S CUSTOMERS FOR ANY CLAIM, LOSS OR DAMAGE OF ANY KIND OR NATURE WHATSOEVER, NOR SHALL THERE BE ANY ABATEMENT OF PURCHASE PRICE, ARISING OUT OF OR IN CONNECTION WITH (1) THE DEFICIENCY OR INADEQUACY OF THE EQUIPMENT FOR ANY PURPOSE WHETHER OR NOT KNOWN OR DISCLOSED TO INTELLIGENT INTERFACES INC., (2) ANY DEFICIENCY OR DEFECT IN THE EQUIPMENT, (3) THE USE OR PERFORMANCE OF THE EQUIPMENT, (4) ANY INTERRUPTION OR LOSS OF SERVICE OR PERFORMANCE OF THE EQUIPMENT, OR (5) ANY LOSS OF BUSINESS OR OTHER CONSEQUENTIAL LOSS OR DAMAGE, EXPENSES, LOST PROFIT, LOST SAVINGS, OR OTHER DAMAGES ARISING OUT OF THE USE OR INABILITY TO USE THE PRODUCT, WHETHER OR NOT RESULTING FROM ANY OF THE FOREGOING. The repair or replacement of a product or a refund of purchase price is your exclusive remedy. The implied warranty of merchantability or fitness is limited to the One-Year duration of this written warranty. Some states or provinces do not allow limitations on the length of an implied warranty. Therefore, the above limitation or exclusion may not apply in your state. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state, or province to province. Intelligent
Interfaces, Inc. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||